GPU Fleet Management Software for Mixed-Vendor Fleets: Inventory, NVIDIA and AMD Job Pools, and Fault Isolation
GPU fleet management software should treat a mixed-vendor GPU fleet as two resource pools in one rack. Heterogeneous GPU cluster management breaks in three places once NVIDIA and AMD nodes share a cluster.
The inventory records both vendors as the same kind of node, the scheduler lets one job span both vendors, and faults reach the wrong diagnostic tool. The fixes follow that order: one inventory schema, job pools that each hold one vendor's GPUs, and fault routing by each node's vendor.
TL;DR: Kubernetes reports NVIDIA GPUs as `nvidia.com/gpu` and AMD GPUs as amd.com/gpu or partition-specific names, so a GPU request matches one vendor's hardware. Keep each distributed job on one vendor, and send each fault to that vendor's diagnostic tool.What Breaks When a Fleet Has Two GPU Vendors
Start with an on-premises Kubernetes cluster that runs each vendor's GPU device plugin plus Kueue, the Kubernetes job-queueing system. The steps below leave cloud-hosted clusters out of scope.
Mixed-vendor fleets fail at three points, and each fix builds on the previous fix:
- Inventory: NVIDIA and AMD nodes differ in driver stack, firmware, GPU interconnect, partition mode and the resource name they report to Kubernetes. A record that reads "GPU node, 8 GPUs" can't tell the team which nodes need a driver update or which resource name places a job on a node.
- Scheduling: A job spread across both vendors inherits two driver stacks and two libraries for moving data between GPUs, NCCL on NVIDIA and RCCL on AMD. Distributed training syncs its GPUs at the end of each iteration, so the slowest GPU sets the pace for the job.
- Fault isolation: NVIDIA health signals come from DCGM (Data Center GPU Manager) and Xid error codes. AMD's come from RDC (ROCm Data Center Tool), amd-smi and the Cluster Validation Framework (CVF). A triage process built for one stack misreads faults on the other vendor's nodes. Power and cooling faults need facility data, the subject of AI DCIM for GPU fleets.
Step 1: Build One GPU Inventory Record for NVIDIA and AMD Nodes
Give each GPU node one record with the same seven fields, filled in with that vendor's values:
- Vendor: decides which diagnostic tool owns the node.
- Model: decides which job queue the node joins when models differ within a vendor.
- Driver stack: tells the team which updates the node needs.
- Firmware: shows which nodes lag behind the vendor's current firmware release.
- GPU interconnect: names the link between GPUs inside the server, which the vendor's tools test for errors.
- Partition mode: records whether the GPUs are split into smaller logical GPUs.
- Resource name: gives the name a job requests to land on the node.
The fields below take different values on each vendor's nodes:
| Field | NVIDIA node | AMD node |
|---|---|---|
| Driver stack | NVIDIA driver with DCGM | ROCm with RDC and amd-smi |
| GPU interconnect | NVLink | Infinity Fabric (xGMI) |
| Partition mode | Partition style, if partitioned | Partition style and the naming mode, single or mixed |
| Resource name | nvidia.com/gpu | amd.com/gpu, or partition names such as amd.com/cpx_nps1 |
In single mode, AMD's GPU Operator device plugin reports AMD GPUs under amd.com/gpu. Mixed mode reports a name per partition style, and AMD's documentation lists mixed mode as supported on nodes whose GPUs use different partition styles.
The inventory works when the team can name, for each node, the diagnostic tool that owns it and the resource name a job needs, without logging in to the node.
Step 2: Separate NVIDIA and AMD Workloads Into Single-Vendor GPU Job Pools
The Kubernetes GPU scheduling guide lists nvidia.com/gpu as a resource that pods request by integer count, and the AMD device plugin reports AMD GPUs under its own names. A job that requests one vendor's resource can't land on the other vendor's GPUs, so the resource name itself keeps jobs in their pool.
Three settings keep each pool to one vendor:
- One Kueue ResourceFlavor per vendor: A ResourceFlavor is Kueue's object for one class of hardware, and Kueue's documentation cites Radeon 7000, Nvidia A100 and T4 GPUs as examples. Define one flavor per vendor, plus one per model where models differ, and tie each queue to its allowed flavors.
- Node taints per vendor: A taint marks a node so the scheduler keeps jobs off it unless a job carries the matching toleration. Taint NVIDIA and AMD nodes separately, and give each vendor's workloads their own toleration.
- One vendor per distributed job: Keep each gang-scheduled job, one whose workers start together or wait together, on one vendor's GPUs. Mixing vendors adds a second driver stack and a second data-transfer library to debug.
WhiteFiber's guidance on heterogeneous AI clouds advises against mixing GPU models in one training job, because a slower GPU holds back the rest at each sync. We extend that advice to mixed vendors on our own judgment.
Kubernetes best practices for AI workloads covers node selectors and GPU resource requests for scheduling.
To test the pools, submit one job requesting nvidia.com/gpu and a second requesting amd.com/gpu, and confirm each lands on its own vendor's nodes. A job requesting both resources should stay in the queue, because each node holds one vendor's GPUs.
Step 3: Route Each GPU Fault to the Vendor's Diagnostic Tool
Route each fault by the vendor in the node's inventory record. Each tool reads its own vendor's GPUs, so a fault on an AMD node needs AMD's tools.
| Node vendor | Tool | What the tool checks |
|---|---|---|
| NVIDIA | DCGM | Per-GPU health checks and diagnostics |
| NVIDIA | Xid codes in the kernel log | Specific faults, such as Xid 74 for an NVLink error |
| AMD | RDC and amd-smi | GPU health and state on one node |
| AMD | CVF | Validation across the cluster |
On NVIDIA nodes, start with DCGM's diagnostics, and run dcgmi nvlink --errors for a GPU's NVLink error counters. The GPU monitoring metrics guide explains DCGM metrics field by field.
On AMD nodes, add CVF for checks across the cluster. AMD's ROCm blog post on CVF lists node eligibility, GPU acceptance, bandwidth between GPUs in a server, network card health, direct memory transfer (RDMA) between servers and multi-node RCCL tests.
CVF runs that RDMA test over InfiniBand or RoCE Ethernet, one network rail at a time.
The same post says DCGM's Level 3 diagnostic runs about 12 minutes per node and doesn't support multi-node NCCL testing. That's AMD's description of a competitor's tool, and we haven't verified the claim.
CVF writes its result to the node label amd.com/cluster-validation-status, set to passed or failed. AMD suggests that schedulers require that label through a node affinity rule, so training jobs land on nodes that passed validation.
To test the routing, simulate a fault on one node of each vendor. Each alert should name that vendor's tool, and the runbook's first command should come from that vendor's stack.
Worked Example: One GPU Fault on Each Vendor's Node
The scenario below is made up for illustration. Two nodes drop their training jobs in the same minute: node-a runs NVIDIA GPUs, and node-b runs AMD GPUs.
On node-a, DCGM raises the alert. The operator pulls the Xid code from the kernel log, finds Xid 74, an NVLink error, and runs DCGM's diagnostic to confirm the fault.
A confirmed fault means draining node-a and requeueing its jobs onto other NVIDIA nodes in the same pool. The requeued job resumes from its last checkpoint if the training script saves one, which is how PyTorch's torchrun provides fault tolerance.
The pool holds NVIDIA nodes alone, so the requeued work can't land on an AMD node with a different driver stack. AIOps for AI infrastructure covers automating that drain, requeue and validation loop.
On node-b, RDC or amd-smi raises the alert. The operator checks per-GPU state with amd-smi, then runs CVF to test bandwidth between GPUs, the network cards and, for a multi-node job, RCCL across servers.
A failed amd.com/cluster-validation-status label keeps node-b out of the pool until repair, provided a node affinity rule reads the label. The investigation moves to the network team when CVF's checks point at the InfiniBand or RoCE network between servers.
The command center decides who gets paged and whether to check GPU, network or facility causes first.
Verification: Three Checks for a Mixed-Vendor GPU Fleet
Run one fleet-wide check per step:
- Inventory check: Pick ten nodes at random and confirm each record predicts the node's diagnostic tool and resource name.
- Pool check: Confirm jobs for each vendor's resource name land on that vendor's nodes, under normal load and during preemption, when the scheduler evicts lower-priority jobs.
- Fault-routing check: Inject one fault per vendor, or wait for a real one, and confirm each alert reaches the right tool without manual correction.
We couldn't find an independent, dated benchmark comparing the operating cost of a mixed NVIDIA and AMD fleet with a single-vendor fleet. The SemiAnalysis InferenceMAX benchmark compares AMD and NVIDIA on cost per million tokens for model serving, a separate question.
Treat a vendor's figure for mixed-fleet operating cost as that vendor's own estimate.
Where zWARE Fits as GPU Fleet Management Software
Zettabyte makes zWARE, so weigh this section with that interest in mind. Each step above runs on vendor tools and Kubernetes components.
zWARE is Zettabyte's GPU fleet management software, with scheduling and monitoring in one layer. Its product page lists multi-cluster federation across heterogeneous GPU domains and workload-to-hardware matching based on real-time system state.
The product page reports 30 to 40% higher effective GPU utilization for typical customers. That figure is Zettabyte's own estimate, and the page leaves out the baseline.
Run the three verification checks on zWARE as on other tools. Ask Zettabyte to confirm per-vendor job pools and fault routing in writing, since the product page doesn't name NVIDIA or AMD.
FAQ: Mixed-Vendor GPU Fleet Management
Can NVIDIA and AMD GPU Nodes Share One Kubernetes Node Pool?
Keep NVIDIA and AMD GPU nodes in separate pools inside one cluster, each pool with its own taint. The two vendors report different resource names, so a job requesting one can't match the other vendor's GPUs.
Does a DCGM Health Check Report on an AMD GPU?
DCGM doesn't cover AMD GPUs, so check AMD nodes with RDC, amd-smi and CVF. Route each diagnostic by the node's vendor label.